ECG-100G Digital Single Channel ECG

  • High-resolution thermal printing array system
  • Frequency response is as high as 150Hz
  • Capable of printing continuously on channel trace and  annotations including lead mark and parameter such as sensitivity, paper speed and filter operation status
  • High resolution digital filter inhibits baseline drift  without affecting ECG waveform  
  • One-touch operation  
  • Concept of floating input circuit meets IEC safety   standard  
  • Rechargeable battery supporting more than 50 patient   examinations  
  • Lead Standard: 12 leads
 Input Circuit   Floating; Protection against Defibrillator effect
  Lead         Standard 12 Leads, Lead change automatically
  Patient Current Leakage     <10μA
  Input Impedance  ≥10ΜΩ 
  Calibrating Voltage   1mV±3% 
  A/D Conversion    12 bit     
  Frequency Response    0.05Hz~150Hz (IEC)
  Time Constant    >3.2seconds 

  CMRR

  >80dB

 >100dB (with filter)

  EMG Filter    35Hz (-3dB) / 25Hz (-3dB) 
  Sensitivity   1/2, 1, 2 (cm/mV), Conversion Deviation5%
  Recording System    Thermal-array          

  8 dots/mm ( vertical ) 

  16 dots/mm ( horizontal, 25mm/sec )

  Paper Speed     25, 50mm/s±3%
  Recording Paper    50mm,20m, high-speed roll      
  Input Circuit Current    ≤50nA   
  Safety Standard   IEC class I, type CF
  Power Supply

  AC: 220V / 110V, 50/60Hz

  DC: 12V rechargeable battery   

  Skin Voltage Tolerance   ±300mV
  Noise Level   <15uVp-p
  Dimensions    310mm×230mm×70mm 
  Dimension of Packing   400mm×280mm×160mm
  Weight   2.75kg  

 Input Circuit   Floating; Protection against Defibrillator effect
  Lead         Standard 12 Leads, Lead change automatically
  Patient Current Leakage     μA
  Input Impedance  ≥10ΜΩ 
  Calibrating Voltage   1mV±3% 
  A/D Conversion    12 bit     
  Frequency Response    0.05Hz~150Hz (IEC)
  Time Constant    >3.2seconds 

  CMRR

  >80dB

 >100dB (with filter)

  EMG Filter    35Hz (-3dB) / 25Hz (-3dB) 
  Sensitivity   1/2, 1, 2 (cm/mV), Conversion Deviation5%
  Recording System    Thermal-array          

  8 dots/mm ( vertical ) 

  16 dots/mm ( horizontal, 25mm/sec )

  Paper Speed     25, 50mm/s±3%
  Recording Paper    50mm,20m, high-speed roll      
  Input Circuit Current    ≤50nA   
  Safety Standard   IEC class I, type CF
  Power Supply

  AC: 220V / 110V, 50/60Hz

  DC: 12V rechargeable battery   

  Skin Voltage Tolerance   ±300mV
  Noise Level   15Vp-p
  Dimensions    310mm×230mm×70mm 
  Dimension of Packing   400mm×280mm×160mm
  Weight   2.75kg  

contec medital system

Contec Medical Systems Co. Ltd

Αναζήτηση